The value of predictive instruments in the screening of acute stroke: an umbrella review on previous systematic reviews

Baratloo, Alireza, Modhamadi, Mobin, Mohammadi, Mohammad, Toloui, Amirmohammad, Neishaboori, Arian Madani, Alavi, Seyedeh Niloufar Rafiei, Nahiyeh, Ali and Yousefifard, Mahmoud (2022) The value of predictive instruments in the screening of acute stroke: an umbrella review on previous systematic reviews. Frontiers in Emergency Medicine, 6 (3).

Full text not available from this repository.

Official URL: https://doi.org/10.18502/fem.v6i3.9400

Abstract

Objective:
Although various predictive instruments have been introduced for early stroke diagnosis, there is no
consensus on their performance. Therefore, we decided to assess the value of predictive instruments in the detection of stroke by conducting an umbrella review.

Method:
A search was performed in the Medline, Embase, Scopus and Web of Science databases by the end of
August 2021 for systematic reviews and meta-analyses. Original articles included in the systematic reviews were
retrieved, summarized and pooled sensitivity, specificity and diagnostic odds ratio were calculated. The level
of evidence was divided into five groups: convincing (class I), highly suggestive (class II), suggestive (class III),
weak (class IV) and non-significant.

Results:
The value of 33 predictive instruments was evaluated. The sample size included in these scoring systems’ assessments varied between 182 and 47072 patients. The level of evidence was class I in one tool, class II
in 18 tools, class III in 2 tools, class IV in 11 tools, and non-significant in one tool. Apart from Med PACS, which
had a low diagnostic value, other tools appeared to be able to detect a stroke. The optimum performance for
diagnosis of stroke was for ROSIER, NIHSS, PASS, FAST, LAMS, RACE and CPSS.

Conclusion:
Convincing to suggestive evidence shows that ROSIER, NIHSS, PASS, FAST, LAMS, RACE and CPSS
have the optimum performance in identifying stroke. Since ROSIER’s calculation is simple and has the highest sensitivity and specificity among those predictive instruments, it is recommended for stroke diagnosis in
pre-hospital and in-hospital settings.