Vertical augmentation with interpositional blocks of anorganic bovine bone vs. 7-mm-long implants in posterior mandibles: 1-year results of a randomized clinical trial

Felice, Pietro, Pellegrino, Gerardo, Checchi, Luigi, Pistilli, Roberto and Esposito, Marco (2010) Vertical augmentation with interpositional blocks of anorganic bovine bone vs. 7-mm-long implants in posterior mandibles: 1-year results of a randomized clinical trial. Clinical Oral Implants Research, 21 (12). pp. 1394-1403. ISSN 09057161

[thumbnail of Publisher's post-print for classroom teaching and internal training purposes at UCLan.] PDF (Publisher's post-print for classroom teaching and internal training purposes at UCLan.) - Published Version
Restricted to Registered users only

1MB

Official URL: http://dx.doi.org/10.1111/j.1600-0501.2010.01966.x

Abstract

Objectives: To evaluate whether 7-mm-long implants could be an alternative to longer implants placed in vertically augmented posterior mandibles.Materials and methods: Sixty patients with posterior mandibular edentulism with 7-8 mm bone height above the mandibular canal were randomized to either vertical augmentation with anorganic bovine bone blocks and delayed 5-month placement of ≥10 mm implants or to receive 7-mm-long implants. Four months after implant placement, provisional prostheses were delivered, replaced after 4 months, by definitive prostheses. The outcome measures were prosthesis and implant failures, any complications and peri-implant marginal bone levels. All patients were followed to 1 year after loading.Results: One patient dropped out from the short implant group. In two augmented mandibles, there was not sufficient bone to place 10-mm-long implants possibly because the blocks had broken apart during insertion. One prosthesis could not be placed when planned in the 7 mm group vs. three prostheses in the augmented group, because of early failure of one implant in each patient. Four complications (wound dehiscence) occurred during graft healing in the augmented group vs. none in the 7 mm group. No complications occurred after implant placement. These differences were not statistically significant. One year after loading, patients of both groups lost an average of 1 mm of peri-implant bone. There no statistically significant differences in bone loss between groups.Conclusions: When residual bone height over the mandibular canal is between 7 and 8 mm, 7 mm short implants might be a preferable choice than vertical augmentation, reducing the chair time, expenses and morbidity. These 1-year preliminary results need to be confirmed by follow-up of at least 5 years.


Repository Staff Only: item control page